Mechanical tests
Failure loads and clamp slip tests, on single components and complete strings.
- 1200 kN horizontal tensile machine, 9 m effective span
- Two 500 kN vertical tensile machines
- 120 t hydraulic press for clamp compression

Testing laboratory
Mechanical, vibration and electrical tests on high-voltage line fittings, to IEC and ANSI standards.
Recognition
IMQ accepts the results of tests performed in our laboratory as the basis for issuing its own certifications.
Every test session is witnessed by IMQ engineers.
Terna specifications: LIN_000M3900 · LIN_00M10000 · LIN_000C3916 · LIN_000M3917 · LIN_0000M808
Horizontal tensile testing
Horizontal tensile testing machine rated at 1200 kN, with a 9-metre effective span, for tests on complete strings and individual components.




Testing areas
Failure loads and clamp slip tests, on single components and complete strings.
Performance, fatigue and efficiency of vibration dampers and spacer dampers.
Heat cycle and power loss tests on high-voltage line fittings, to IEC and ANSI standards.
Dimensional checks, galvanising and material inspection during acceptance testing.
Equipment
Accredited external laboratories
Test reports are available for similar 132 kV and 400 kV strings, issued by certified laboratories. New type tests are performed to the latest IEC standards and contract specifications.
On complete suspension and tension strings.
On complete suspension and tension strings.
On complete suspension and tension strings.
On compression tension clamps and mid-span joints.
On suspension clamps.
On suspension and tension string components.


Third-party testing